Category Bids

Electrical & power systems — open bids

781 open bids, newest first. Full details live here — you only leave for the official posting when you bid.

CABLE ASSEMBLY,PRINTED

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 5995016156322 CABLE ASSEMBLY,PRINTED: Line 0001 Qty 6 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0171 DAYS ADO Approved source is 0WEC9 75652A-00. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

WIRING HARNESS

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 6150015028180 WIRING HARNESS: Line 0001 Qty 17 UI EA Deliver To: DLA DISTRIBUTION JACKSONVILLE By: 0306 DAYS ADO This is a source controlled drawing item. Approved sources are 09526 AA3676-3; 24735 AA3676-3. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. The items furnished must meet the requirements of the drawing cited in the solicitation. Digitized drawings and Military Specifications and Standards may be retrieved, or ordered, electronically. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

CABLE ASSEMBLY,SPECIAL

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 6150012670319 CABLE ASSEMBLY,SPECIAL: Line 0001 Qty 16 UI EA Deliver To: DLA DISTRIBUTION JACKSONVILLE By: 0122 DAYS ADO Approved sources are 08484 BL-11585-1; 0LGT4 MAC240319. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

CABLE ASSEMBLY-SWITCH,

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 6150012502772 CABLE ASSEMBLY-SWITCH,: Line 0001 Qty 11 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0696 DAYS ADO Line 0002 Qty 1 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0075 DAYS ADO Line 0003 Qty 1 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0681 DAYS ADO All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

WIRING HARNESS,BRANCHE

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/SolicitationService-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)

Proposed procurement for NSN 6150016744580 WIRING HARNESS,BRANCHE: Line 0001 Qty 21 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0381 DAYS ADO Line 0002 Qty 1 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0090 DAYS ADO All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

WIRING HARNESS,BRANCHE

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/SolicitationService-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)

Proposed procurement for NSN 6150016334902 WIRING HARNESS,BRANCHE: Line 0001 Qty 9 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0171 DAYS ADO The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Digitized drawings and Military Specifications and Standards may be retrieved, or ordered, electronically. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

CORD ASSEMBLY,ELECTRIC

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 5995016201411 CORD ASSEMBLY,ELECTRIC: Line 0001 Qty 137 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0171 DAYS ADO Approved sources are 60240 G030-1570-02; 7L772 G030-1570-02. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

WIRING HARNESS,BRANCHE

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/SolicitationSmall Business Set Aside - Total

Proposed procurement for NSN 6150015416997 WIRING HARNESS,BRANCHE: Line 0001 Qty 20 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0300 DAYS ADO Line 0002 Qty 1 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0120 DAYS ADO All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

PC IO SPECL COMPASS

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 5998016196157 PC IO SPECL COMPASS: Line 0001 Qty 7 UI EA Deliver To: W1A8 DLA DIST SAN JOAQUIN By: 0171 DAYS ADO Approved source is 03956 4304360. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

WIRING HARNESS,BRANCHE

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/SolicitationService-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)

Proposed procurement for NSN 6150011448900 WIRING HARNESS,BRANCHE: Line 0001 Qty 78 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0303 DAYS ADO The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Digitized drawings and Military Specifications and Standards may be retrieved, or ordered, electronically. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

WIRING HARNESS,BRANCHE

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/SolicitationSmall Business Set Aside - Total

Proposed procurement for NSN 5995016741512 WIRING HARNESS,BRANCHE: Line 0001 Qty 10 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0221 DAYS ADO Line 0002 Qty 1 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0020 DAYS ADO All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

INSULATOR,PLATE

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 5970016582567 INSULATOR,PLATE: Line 0001 Qty 10 UI EA Deliver To: DLA DISTRIBUTION CHERRY POINT By: 0171 DAYS ADO Approved source is 55820 4951902-2. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

CABLE ASSEMBLY,TRAN

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 5995010688008 CABLE ASSEMBLY,TRAN: Line 0001 Qty 12 UI EA Deliver To: DLA DISTRIBUTION DEPOT HILL By: 0102 DAYS ADO Approved source is 98810 123-0246-05. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

CABLE ASSEMBLY,SPECIAL

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/SolicitationSmall Business Set Aside - Total

Proposed procurement for NSN 6150992977668 CABLE ASSEMBLY,SPECIAL: Line 0001 Qty 13 UI EA Deliver To: W0LX ANNISTON DEPOT PROP DIV By: 0005 DAYS ADO Approved source is K0824 CS3144. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

CABLE ASSEMBLY,SPECIAL

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 6150015640269 CABLE ASSEMBLY,SPECIAL: Line 0001 Qty 8 UI EA Deliver To: W1A8 DLA DIST SAN JOAQUIN By: 0171 DAYS ADO Approved source is 78286 96550-01822-106. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

DISTRIBUTION BOX

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 6110015449443 DISTRIBUTION BOX: Line 0001 Qty 7 UI EA Deliver To: W1A8 DLA DISTRIBUTION By: 0171 DAYS ADO Approved source is 78286 70600-01413-041. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

WIRING HARNESS,BRANCHE

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 6150016776345 WIRING HARNESS,BRANCHE: Line 0001 Qty 16 UI EA Deliver To: DLA DISTRIBUTION DEPOT OKLAHOMA By: 0171 DAYS ADO Approved source is 82918 458-59661-1. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

CABLE ASSEMBLY,SPECIAL

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/Solicitation

Proposed procurement for NSN 5995016096397 CABLE ASSEMBLY,SPECIAL: Line 0001 Qty 10 UI EA Deliver To: W1A8 DLA DIST SAN JOAQUIN By: 0171 DAYS ADO Approved source is 90536 C207. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

DISPLAY,OPTOELECTRONIC

Department of Defense · DLA Aviation  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsCombined Synopsis/SolicitationSmall Business Set Aside - Total

Proposed procurement for NSN 5980015304040 DISPLAY,OPTOELECTRONIC: Line 0001 Qty 3 UI EA Deliver To: DLA DISTRIBUTION SAN DIEGO By: 0527 DAYS ADO Approved source is 07187 8527420-902. The solicitation is an RFQ and will be available at the link provided in this notice. Hard copies of this solicitation are not available. Specifications, plans, or drawings are not available. All responsible sources may submit a quote which, if timely received, shall be considered. Quotes must be submitted electronically.

Closes Nov 13, 2026
Read more →

IEM/MMM TACTICL EHF

Department of Defense · Navsup Weapon Systems Support MECH  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsPresolicitationSmall Business Set Aside - Total

NSN 1H-5935-015733988-L1, TDP VER 008, QTY 62 EA, DELIVER TO N50286, PORTSMOUTH NAVAL SHIPYARD L1SS, KITTERY, ME 03904. The proposed contract action is for supplies or services for which the Government intends to solicit and negotiate with only one source under the authority of FAR 6.302-1. All responsible sources may identify their interest and capability to respond to the requirement or submit proposals, quotations or capability statements. This notice of intent is not a request for competitive proposals. However, all proposals received within 45 days (30 days if award is issued under an existing Basic Ordering Agreement (BOA) after date of publication of this synopsis will be considered by the Government. A determination by the Government not to compete with this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. Award will be made only if the offeror, the product/service, or the manufacturer meets the qualification requirement(s) at time of award, in accordance with FAR clause 52.209-1. The solicitation identifies the office where additional information can be obtained concerning qualification requirements and is cited in each individual solicitation. Based upon market research, the Government is not using the policies contained in FAR Part 12, Acquisition of Commercial Items, in its solicitation for the described supplies or services. However, interested persons may identify to the contracting officer their interest and capability to satisfy the Government's requirement with a commercial item within 15 days of this notice. One or more of the items under this acquisition is subject to: Free Trade Agreements, if DFARS clause 252.225-7036 Buy American Act--Free Trade Agreements--Balance of Payments Program, is included in the solicitation. The World Trade Organization Government Procurement Agreement and Free Trade Agreements, if DFARS clause 252.225-7021 Trade Agreements, is included in the solicitation.

Closes Nov 13, 2026 · 2:00 PM ET
Read more →

IEM/MMM TACTICL EHF

Department of Defense · Navsup Weapon Systems Support MECH  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsSolicitation

CONTACT INFORMATION|4|N743.49|WVE|771-229-0573|benjamin.t.spangler.civ@us.navy.mil| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (DEC 2014)|1|See specification sections C and E.| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| STOP-WORK ORDER (AUG 1989)|1|| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material |N/A|TBD|N00104|TBD|N39040 - Certifications, S4306A - Material |N50286|TBD|133.2|N/A|N/A|N39040 - Certifications |N/A |N/A|SEE DD FORM 1423 |PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL BENJAMIN.T.SPANGLER.CIV@US.NAVY.MIL| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| MANDATORY USE OF WORKFLOW PRO (WFP) MOD ASSIST MODULE|1|| VALUE ENGINEERING (JUN 2020)|3|||| INTEGRITY OF UNIT PRICES (NOV 2021)|1|| EQUAL OPPORTUNITY FOR VETERANS (DEV 2026-O0040)(FEB 2026)|4||||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One year from date of delivery.|One year from date of delivery.||||| SMALL BUSINESS SUBCONTRACTING PLAN (DEV 2026-O0037)(FEB 2026)|4||||| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES (DEV 2026-O0040)(FEB 2026)|4||||| TRANSPORTATION OF SUPPLIES BY SEA (OCT 2024)|2||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)-BASIC (DEV 2026-O0037)(FEB 2026))|2||| WARRANTY OF DATA-BASIC (DEVIATION 2026-O0035) (FEB 2026)|2||| CONTRACTOR PURCHASING SYSTEM ADMINISTRATION-BASIC (DEVIATION 2026-O0015)|1|| REQUIREMENTS FOR CERTIFIED COST OR PRICING DATA AND DATA OTHER THAN CERTIFIED COST OR PRICING DATA-MODIFICATIONS (DEV 2026-O0048)(MAR 2026))|7|||||||| SECURITY PROHIBITIONS AND EXCLUSIONS (CLASS DEVIATION 2026-O0025)(FEB 2026)|7|||||||| PERFORMANCE-BASED PAYMENTS (APR 2012)|1|| LIST OF AWARD ATTACHMENTS|5|||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (DEVIATION 2026-O0043)(FEB 2026))|13|||||||||||||| ROYALTY INFORMATION (APR 1984)|1|| COST ACCOUNTING STANDARDS NOTICES AND CERTIFICATION (DEV 2026-O0006)(FEB 2026)|1|| REQUIREMENTS FOR SUBMISSION OF PROPOSALS VIA ELECTRONIC MEDIA (JAN 2018)|1|Electronic mail| TYPE OF CONTRACT (DEV 2026-O0045)(MAR 2026)|1|| ALTERATIONS IN SOLICITATION (APR 1984)|3|||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| ONLY ONE OFFER (DEVIATION 2026-O0048)(MAR 2026)|1|| 1.DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg. 2. Portsmouth NSY's DODAAC has changed from N00102 to N50286. Any reference toN00102 within this order should be updated to N50286. 3. The following proposed delivery schedule applies: Submission of Certification Data CDRLs will be on or before 20 days prior to scheduled delivery. PNSY review/acceptance of Certification CDRLs 6 working days after receipt of Certification DD 1423 CDRLs. Final delivery of material will be on or before 365 days after effective date of the resulting contract. 4. Any contract awarded as a result of this solicitation will be "DO" rated order; "DO" rated order certified for national defense use under the Defense Priorities and Allocations System (DPAS). 5. The complete RFP package must be signed and returned prior to the closing date. Emailed or faxed proposals are acceptable. NECO quotes will NOT be accepted and will be determined non-responsive. \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.2.3 The documents and drawings listed below under DRAWING NO. are not provided with this Contract/Purchase order. DRAWING NO CAGE REV DISTR CD ;LB01504 16275 K B LB01517 16275 J B LB01527 16275 C B LB01545 16275 E B LB01883 16275 B B LB01882 16275 - B LB01884 16275 A B LB01544 16275 P B LB01600 16275 K B ITI-500 16275 V B QA-1129 16275 E B; DOCUMENT REF DATA=FED-STD-H28 | | |B |190424|A| | | DOCUMENT REF DATA=FED-STD-H28 |0020| |B |941221|A| |01| DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=QQ-N-286 | | |G |001207|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | | DOCUMENT REF DATA=MIL-STD-2132 | | |D |080310|A| |01| DOCUMENT REF DATA=SAE AMS 5666 | | |J |161101|A| | | DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A| 1| | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=A-A-59004 | | |B |181118|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|C| |01| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3. REQUIREMENTS 3.1 ;Hull Penetrating Assembly must be in accordance with LaBarge INC. Drawing LB01504, except as amplified or modified herein.; 3.2 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: Part - ;Body, Item 2 on Drawing LB01527; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of Drawing LB01527, Note 9; Part - ;Header, Find 1 on Drawing LB01600; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01600, Note 8 or SAE AMS 5666, Round Bar, Hot Finished and Annealed and Meeting the Mechanical Properties of drawing LB01600, Note 9; Part - ;Washer, Drawing LB01883; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01883, Note 6; Part - ;Hex Nut, Drawing LB01882; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01882, Note 6; Part - ;Spacer, Drawing LB01884; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01884, Note 6; 3.3 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings is still required, but certifications are only required as listed below. Test - ;Electrical Testing; Item - ;Each Hull Penetrating Assembly; Performance - ;INSPECTION / TEST INSTRUCTIONS ITI-500; Acceptance - ;INSPECTION / TEST INSTRUCTIONS ITI-500; Test - ;Hydrostatic Pressure Test; Item - ;Each Hull Penetrating Assembly; Performance - ;INSPECTION / TEST INSTRUCTIONS ITI-500 and QA-1129; Acceptance - ;INSPECTION / TEST INSTRUCTIONS ITI-500; Test - ;Tensile Test (after glass sealing and age hardening processes); Item - ;One test specimen for each combination of starting material heat lot and age hardening batch when headers are made from QQ-N-286; Performance - ;Drawing LB01544, Note 13; Acceptance - ;Drawing LB01544, Note 13; Test - ;Tensile Test (after glass sealing); Item - ;One test specimen for each heat lot when headers are made from SAE AMS 5666; Performance - ;Drawing LB01544, Note 14; Acceptance - ;Drawing LB01544, Note 14; Test - ;Hardness test (after glass sealing and age hardening processes); Item - ;Each header when made from QQ-N-286; Performance - ;Drawing LB01544, Note 13; Acceptance - ;Drawing LB01544, Note 13; Test - ;Hardness test (after glass sealing); Item - ;Each header when made from SAE AMS 5666; Performance - ;Drawing LB01544, Note 14; Acceptance - ;Drawing LB01544, Note 14; Attribute - ;Time/Temperature Heat Treatment Record; Item - ;Each header when made from QQ-N-286; Performance - ;Drawing LB01544, Note 13; Attribute - Annealing and Age Hardening Item - ;Body, Item 2 on Drawing LB01527; Header Find 1 on Drawing LB01600 (when made from QQ-N-286); Washer, Drawing LB01883; Hex Nut, Drawing LB01882; and Spacer, Drawing LB01884; Performance - QQ-N-286 Test - Ultrasonic Inspection on Starting Material Item - ;All Items requiring certification made from QQ-N-286 with a diameter or minimum distance between parallel surfaces of 4 inches or greater of the starting material, or when required by a drawing or specification invoked elsewhere in this contract; Performance - T9074-AS-GIB-010/271 or MIL-STD-2132, and QQ-N-286 Acceptance - QQ-N-286 Test - Non-Destructive Tests Item - ;Weld Repair and/or Production Weld (as applicable); Performance - Per applicable fabrication specification Acceptance - Per applicable fabrication specification 3.4 The pressure tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For pressure tests below 100 PSIG, the pressure tolerance must be +1 PSIG / -0 PSIG. For pressure tests at or above 100 PSIG up to and including 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 50 PSIG. For pressure tests above 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG, rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 200 PSIG. The pressure test time tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure test time tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For a test duration up to and including 1 hour, the tolerance must be +5 minutes / - 0 minutes. For a test duration of more than 1 hour up to and including 24 hours, the tolerance must be +30 minutes / - 0 minutes. For a test duration of more than 24 hours, the tolerance must be +60 minutes / - 0 minutes. 3.5 Welding or Brazing - When welding, brazing, and allied processes are required, as invoked by Section C paragraph 3 requirements, they must be in accordance with S9074-AR-GIB-010A/278, 0900-LP-001-7000 for brazing of piping and pressure vessel applications, or S9074-AQ-GIB-010/248 for brazing of other applications. For all production and repair welding and brazing, personnel and procedures must be qualified under S9074-AQ-GIB-010/248 or 0900-LP-001-7000, as applicable. Repair welding is not permitted on ;QQ-N-286 material; . Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.6 Internal Threads - All internal threads must be formed by cutting. Cold forming of internal threads is not acceptable. 3.7 Thread Inspection Requirements - All threads on threaded parts must be inspected using appropriate inspection methods, inspection systems, and inspection gages/instruments in accordance with FED-STD-H28 series. Substitution of thecommercial equivalent inspection in accordance with ASME B1 series is acceptable. 3.7.1 System 21 of FED-STD-H28/20 must be used as a minimum inspection requirement for threads when the design drawing or design specification does not specify an inspection requirement. 3.7.2 For Navy and Shipyard drawings, system 21 of FED-STD-H28/20 may be substituted for System 22 without further Navy approval when the design drawing invokes System 22 and does not cite governing specifications that specifically require system 22. System 22 of FED-STD-H28/20 must be used when the drawing references other governing specifications that specifically require System 22, such as certain thread types of MIL-DTL-1222. 3.7.3 A written request for concurrence must be submitted when utilizing alternative measuring equipment or measuring systems not applicable to the specified inspection system. 3.8 Thread Lubricant - Thread lubricants containing molybdenum disulfide must not be used on this material. Bacteria in water, especially seawater, causes molybdenum disulfide to break down. The by-products of the breakdown form compounds which attack the fasteners. Anti-galling compound A-A-59004 must be used as a replacement when thread lubricant is required for assembly. 3.9 O-ring grooves and mating sealing surfaces must be inspected per the contractually invoked drawings or specifications. When the drawings or specifications do not provide specific defect criteria or state that no defects are allowed, the General Acceptance Criteria (GAC) standard must be used for inspecting O-ring grooves and mating sealing surfaces only. Repairs to sealing surfaces and O-ring grooves with unacceptable defects may be accomplished within the limits of the size and tolerances provided in the applicable drawing. Repairs thatwould exceed these limits require approval (including final dimensions). The data that is red lined (crossed out) is excluded from the GAC for this contract and is not to be used for acceptance or rejection criteria. The GAC document is identified as Contract Support Library Reference Number CSD008 at https://register.nslc.navy.mil/ 3.10 Slow Strain Rate Tensile Test Laboratories - The Slow Strain Rate Tensile Test of QQ-N-286 must be performed by one of the following laboratories: Huntington Alloys, a Special Metals Company Attn: Bill Bolenr 3200 Riverside Drive Huntington, WV 257059 Phone: (304) 526-5889 FAX: (304) 526-5973 Metallurgical Consultants, Inc. Attn: W. M. Buehler 4820 Caroline PO Box 88046 Houston, TX 77288-0046 Phone: (713) 526-6351 FAX: (713) 526-2964 Naval Surface Warfare Center, Carderock Division Attn: Eric Focht Code 614 9500 Macarthur Blvd West Bethesda, MD 20817-5700 Phone: (301) 227-5032 FAX: (301) 227-5576 Teledyne Allvac Attn: Dr. W. D. Cao 2020 Ashcraft Ave. Monroe, NC 28110 Phone: (704) 289-4511 FAX: (704) 289-4269 Westmoreland Mechanical Testing and Research Inc. Attn: Andrew Wisniewski P.O. Box 388 Youngstown, PA 15696-0388 Mannesmann Rohrenwerke Mannesmann Forschungsinstitut (MFI) Attn: Dr. Weiss Postfach 251160 47251 Duisburg Germany Phone: 011-49-0203-9993194 FAX: 011-49-0203-9994415 ThyssenKrupp VDM USA, Inc. Attn: D. C. Agarwal 11210 Steeplecrest Drive, Suite 120 Houston, TX 77065-4939 Phone: (281) 955-6683 3.11 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited. 3.11.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. 3.12 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. 3.13 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.13.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.13.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted to the NAVSUP WSS Contracting Specialist via eMail. 3.13.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.14 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.15 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results. Certification must include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments must be identified to weld joint and layer. 3.16 Welding Requirements - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval. In addition, the CONSUMED WELD METAL C of C as defined below must be submitted as part of the certification OQE package submitted by the Contractor. Note: These requirements do not apply to tack/spot welds. 3.16.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair). 3.16.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must be submitted at the same time. Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor must state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e. ''WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC'.' WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ'') 3.16.3 The PCO's authorization for the use of weld procedure(s) and qualification data for the specific application as submitted does not mitigate the vendors responsibility to comply with the requirements of S9074-AQ-GIB-010, S9074-AR-GIB-010A/278,248d the contract. 3.16.4 Authority for the repair of Special Repairs in castings, the repair of wrought material, or the repair of forged material must be obtained via request for waiver from the Procurement Contracting Officer. This request must describe the defect; including size, depth, location, and a description of the proposed repair. Repairs deemed minor or nominal in accordance with S9074-AR-GIB-010/278 can be made at contractor discretion in accordance with S9074-AR-GIB-010/278 requirements; however, Weld Procedure Specification (WPS) and Procedure Qualification Record (PQR) submittals are still required. This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application. 3.16.5 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 72 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 72 hour time limit may be modified upon mutual agreement between the vendor and DCMA. 3.16.6 When drawings require hardfacing surface Iron or Nickel content not to exceed 5%, the contractor must verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results must be submitted as part of the qualification data. 3.16.7 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs clearly showing the fusion area) must be submitted for review and show consistent, minimized dilution. All essential elements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution must be in the qualification data and weld procedure, with strict limits placed on each essential element. 3.16.8 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278. 3.16.9 When production or repair welding is required on titanium materials, theapplicable fabrication plan, facilities procedure, training plan, and active welder qualification must also be submitted for review and approval. 3.16.10 If the contractor's fabrication plan, facilities procedure, training plan, or active welder qualification has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the applicable documentation to expedite the approval process. The approval letter must reference the applicable documentation. Prior approval does not guarantee acceptance for this or any future contracts. The contractor's fabrication plan, facilities procedure, training plan, and active welder qualification must be submitted at the same time as the applicable welding procedure(s) and weld procedure qualification data. All documentation must be submitted in a commercially available electronic format, such as Adobe Acrobat PDF. 3.16.11 A Certificate of Compliance is required for all weld filler metals used for production or repair welding, and must include the following: a) Filler Metal LOT number(s) b) Specification and Type c) A positive statement that the vendor has obtained OQE and verified that each LOT of weld filler material conforms to specification requirements. d) A positive statement verifying that the weld filler metals were the correct material type or grade prior to consumption. 3.16.12 When production welds or repair welds are performed by a subcontractor, the requirement for submission of all certification documentation required herein must be passed down to the subcontractor. 3.17 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate. 3.17.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/nonacceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order. 3.17.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor must, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative. 3.17.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award of any contract/purchase order. Suppliers that have a copy of their current quality system procedures on file at the Procuring Activity may request the PCO waive this requirement. 3.17.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately. 3.17.5 Any changes made by the Contractor to a qualified quality system will require re-submittal to the PCO and concurrence by the Government Quality Assurance Representative prior to adoption. 3.18 Contractor Inspection Requirements - The Contractor must maintain adequate records of all inspections and tests. The records must indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected and the nature of corrective action taken as appropriate. Inspection records must be traceable to the material inspected. 3.18.1 The supplier's gages, measuring and test equipment must be made available for use by the Government representative when required to determine conformance with Contract requirements. When conditions warrant, the supplier's personnel must be made available for operations of such devices and for verification of their accuracy and condition. 3.18.2 All documents and reference data applicable to this contract must be available for review by the Government representative. Copies of documents required for Government inspection purposes must be furnished in accordance with the instructions provided by the Government representative. 3.19 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured or performed within the contractor's facility. Such inspection can only be requested by or under authorization of the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies being purchased. When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents must be annotated with the following statement: "A Government inspection is required prior to shipment from your plant. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately." 3.19.1 The prime contractor's program must include procedures to assess the capability of the prospective suppliers to produce the products or supply the services in accordance with the contract, prior to the issuance of any purchase document. 3.19.2 Each sub-tier supplier of material or services for items in Section 3 of this contract must be subjected to a periodic review or audit by the Prime to determine the continued capability of the supplier to control the quality of the products or services specified in the purchase order or contract. 3.19.3 The prime contractor must ensure that the purchased product conformsto specified purchase requirements and this contract. The type and extent of control applied to the supplier and the purchased product must be dependent upon the effect of the purchased product on the end item represented by this contract. 3.19.4 The prime contractor must evaluate the requireme...

Closes Nov 13, 2026 · 2:00 PM ET
Read more →

IEM/MMM TACTICL EHF

Department of Defense · Navsup Weapon Systems Support MECH  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsSolicitation

CONTACT INFORMATION|4|N743.49|WVE|771-229-0573|benjamin.t.spangler.civ@us.navy.mil| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (DEC 2014)|1|See specification sections C and E.| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| STOP-WORK ORDER (AUG 1989)|1|| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material |N/A|TBD|N00104|TBD|N39040 - Certifications, S4306A - Material |N50286|TBD|133.2|N/A|N/A|N39040 - Certifications |N/A |N/A|SEE DD FORM 1423 |PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL BENJAMIN.T.SPANGLER.CIV@US.NAVY.MIL| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| MANDATORY USE OF WORKFLOW PRO (WFP) MOD ASSIST MODULE|1|| VALUE ENGINEERING (JUN 2020)|3|||| INTEGRITY OF UNIT PRICES (NOV 2021)|1|| EQUAL OPPORTUNITY FOR VETERANS (DEV 2026-O0040)(FEB 2026)|4||||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One year from date of delivery.|One year from date of delivery.||||| SMALL BUSINESS SUBCONTRACTING PLAN (DEV 2026-O0037)(FEB 2026)|4||||| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES (DEV 2026-O0040)(FEB 2026)|4||||| TRANSPORTATION OF SUPPLIES BY SEA (OCT 2024)|2||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)-BASIC (DEV 2026-O0037)(FEB 2026))|2||| WARRANTY OF DATA-BASIC (DEVIATION 2026-O0035) (FEB 2026)|2||| CONTRACTOR PURCHASING SYSTEM ADMINISTRATION-BASIC (DEVIATION 2026-O0015)|1|| REQUIREMENTS FOR CERTIFIED COST OR PRICING DATA AND DATA OTHER THAN CERTIFIED COST OR PRICING DATA-MODIFICATIONS (DEV 2026-O0048)(MAR 2026))|7|||||||| SECURITY PROHIBITIONS AND EXCLUSIONS (CLASS DEVIATION 2026-O0025)(FEB 2026)|7|||||||| PERFORMANCE-BASED PAYMENTS (APR 2012)|1|| LIST OF AWARD ATTACHMENTS|5|||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (DEVIATION 2026-O0043)(FEB 2026))|13|||||||||||||| ROYALTY INFORMATION (APR 1984)|1|| COST ACCOUNTING STANDARDS NOTICES AND CERTIFICATION (DEV 2026-O0006)(FEB 2026)|1|| REQUIREMENTS FOR SUBMISSION OF PROPOSALS VIA ELECTRONIC MEDIA (JAN 2018)|1|Electronic mail| TYPE OF CONTRACT (DEV 2026-O0045)(MAR 2026)|1|| ALTERATIONS IN SOLICITATION (APR 1984)|3|||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| ONLY ONE OFFER (DEVIATION 2026-O0048)(MAR 2026)|1|| This amendment is issued to update the quantity. \ This amendment is issued to extend the closing date. \ 1.DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg. 2. Portsmouth NSY's DODAAC has changed from N00102 to N50286. Any reference toN00102 within this order should be updated to N50286. 3. The following proposed delivery schedule applies: Submission of Certification Data CDRLs will be on or before 20 days prior to scheduled delivery. PNSY review/acceptance of Certification CDRLs 6 working days after receipt of Certification DD 1423 CDRLs. Final delivery of material will be on or before 365 days after effective date of the resulting contract. 4. Any contract awarded as a result of this solicitation will be "DO" rated order; "DO" rated order certified for national defense use under the Defense Priorities and Allocations System (DPAS). 5. The complete RFP package must be signed and returned prior to the closing date. Emailed or faxed proposals are acceptable. NECO quotes will NOT be accepted and will be determined non-responsive. \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.2.3 The documents and drawings listed below under DRAWING NO. are not provided with this Contract/Purchase order. DRAWING NO CAGE REV DISTR CD ;LB01504 16275 K B LB01517 16275 J B LB01527 16275 C B LB01545 16275 E B LB01883 16275 B B LB01882 16275 - B LB01884 16275 A B LB01544 16275 P B LB01600 16275 K B ITI-500 16275 V B QA-1129 16275 E B; DOCUMENT REF DATA=FED-STD-H28 | | |B |190424|A| | | DOCUMENT REF DATA=FED-STD-H28 |0020| |B |941221|A| |01| DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=QQ-N-286 | | |G |001207|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | | DOCUMENT REF DATA=MIL-STD-2132 | | |D |080310|A| |01| DOCUMENT REF DATA=SAE AMS 5666 | | |J |161101|A| | | DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A| 1| | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=A-A-59004 | | |B |181118|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|C| |01| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3. REQUIREMENTS 3.1 ;Hull Penetrating Assembly must be in accordance with LaBarge INC. Drawing LB01504, except as amplified or modified herein.; 3.2 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: Part - ;Body, Item 2 on Drawing LB01527; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of Drawing LB01527, Note 9; Part - ;Header, Find 1 on Drawing LB01600; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01600, Note 8 or SAE AMS 5666, Round Bar, Hot Finished and Annealed and Meeting the Mechanical Properties of drawing LB01600, Note 9; Part - ;Washer, Drawing LB01883; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01883, Note 6; Part - ;Hex Nut, Drawing LB01882; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01882, Note 6; Part - ;Spacer, Drawing LB01884; Material - ;QQ-N-286, Form 2, Annealed and Age Hardened and Meeting the Mechanical Properties of drawing LB01884, Note 6; 3.3 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings is still required, but certifications are only required as listed below. Test - ;Electrical Testing; Item - ;Each Hull Penetrating Assembly; Performance - ;INSPECTION / TEST INSTRUCTIONS ITI-500; Acceptance - ;INSPECTION / TEST INSTRUCTIONS ITI-500; Test - ;Hydrostatic Pressure Test; Item - ;Each Hull Penetrating Assembly; Performance - ;INSPECTION / TEST INSTRUCTIONS ITI-500 and QA-1129; Acceptance - ;INSPECTION / TEST INSTRUCTIONS ITI-500; Test - ;Tensile Test (after glass sealing and age hardening processes); Item - ;One test specimen for each combination of starting material heat lot and age hardening batch when headers are made from QQ-N-286; Performance - ;Drawing LB01544, Note 13; Acceptance - ;Drawing LB01544, Note 13; Test - ;Tensile Test (after glass sealing); Item - ;One test specimen for each heat lot when headers are made from SAE AMS 5666; Performance - ;Drawing LB01544, Note 14; Acceptance - ;Drawing LB01544, Note 14; Test - ;Hardness test (after glass sealing and age hardening processes); Item - ;Each header when made from QQ-N-286; Performance - ;Drawing LB01544, Note 13; Acceptance - ;Drawing LB01544, Note 13; Test - ;Hardness test (after glass sealing); Item - ;Each header when made from SAE AMS 5666; Performance - ;Drawing LB01544, Note 14; Acceptance - ;Drawing LB01544, Note 14; Attribute - ;Time/Temperature Heat Treatment Record; Item - ;Each header when made from QQ-N-286; Performance - ;Drawing LB01544, Note 13; Attribute - Annealing and Age Hardening Item - ;Body, Item 2 on Drawing LB01527; Header Find 1 on Drawing LB01600 (when made from QQ-N-286); Washer, Drawing LB01883; Hex Nut, Drawing LB01882; and Spacer, Drawing LB01884; Performance - QQ-N-286 Test - Ultrasonic Inspection on Starting Material Item - ;All Items requiring certification made from QQ-N-286 with a diameter or minimum distance between parallel surfaces of 4 inches or greater of the starting material, or when required by a drawing or specification invoked elsewhere in this contract; Performance - T9074-AS-GIB-010/271 or MIL-STD-2132, and QQ-N-286 Acceptance - QQ-N-286 Test - Non-Destructive Tests Item - ;Weld Repair and/or Production Weld (as applicable); Performance - Per applicable fabrication specification Acceptance - Per applicable fabrication specification 3.4 The pressure tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For pressure tests below 100 PSIG, the pressure tolerance must be +1 PSIG / -0 PSIG. For pressure tests at or above 100 PSIG up to and including 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 50 PSIG. For pressure tests above 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG, rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 200 PSIG. The pressure test time tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure test time tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For a test duration up to and including 1 hour, the tolerance must be +5 minutes / - 0 minutes. For a test duration of more than 1 hour up to and including 24 hours, the tolerance must be +30 minutes / - 0 minutes. For a test duration of more than 24 hours, the tolerance must be +60 minutes / - 0 minutes. 3.5 Welding or Brazing - When welding, brazing, and allied processes are required, as invoked by Section C paragraph 3 requirements, they must be in accordance with S9074-AR-GIB-010A/278, 0900-LP-001-7000 for brazing of piping and pressure vessel applications, or S9074-AQ-GIB-010/248 for brazing of other applications. For all production and repair welding and brazing, personnel and procedures must be qualified under S9074-AQ-GIB-010/248 or 0900-LP-001-7000, as applicable. Repair welding is not permitted on ;QQ-N-286 material; . Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.6 Internal Threads - All internal threads must be formed by cutting. Cold forming of internal threads is not acceptable. 3.7 Thread Inspection Requirements - All threads on threaded parts must be inspected using appropriate inspection methods, inspection systems, and inspection gages/instruments in accordance with FED-STD-H28 series. Substitution of thecommercial equivalent inspection in accordance with ASME B1 series is acceptable. 3.7.1 System 21 of FED-STD-H28/20 must be used as a minimum inspection requirement for threads when the design drawing or design specification does not specify an inspection requirement. 3.7.2 For Navy and Shipyard drawings, system 21 of FED-STD-H28/20 may be substituted for System 22 without further Navy approval when the design drawing invokes System 22 and does not cite governing specifications that specifically require system 22. System 22 of FED-STD-H28/20 must be used when the drawing references other governing specifications that specifically require System 22, such as certain thread types of MIL-DTL-1222. 3.7.3 A written request for concurrence must be submitted when utilizing alternative measuring equipment or measuring systems not applicable to the specified inspection system. 3.8 Thread Lubricant - Thread lubricants containing molybdenum disulfide must not be used on this material. Bacteria in water, especially seawater, causes molybdenum disulfide to break down. The by-products of the breakdown form compounds which attack the fasteners. Anti-galling compound A-A-59004 must be used as a replacement when thread lubricant is required for assembly. 3.9 O-ring grooves and mating sealing surfaces must be inspected per the contractually invoked drawings or specifications. When the drawings or specifications do not provide specific defect criteria or state that no defects are allowed, the General Acceptance Criteria (GAC) standard must be used for inspecting O-ring grooves and mating sealing surfaces only. Repairs to sealing surfaces and O-ring grooves with unacceptable defects may be accomplished within the limits of the size and tolerances provided in the applicable drawing. Repairs thatwould exceed these limits require approval (including final dimensions). The data that is red lined (crossed out) is excluded from the GAC for this contract and is not to be used for acceptance or rejection criteria. The GAC document is identified as Contract Support Library Reference Number CSD008 at https://register.nslc.navy.mil/ 3.10 Slow Strain Rate Tensile Test Laboratories - The Slow Strain Rate Tensile Test of QQ-N-286 must be performed by one of the following laboratories: Huntington Alloys, a Special Metals Company Attn: Bill Bolenr 3200 Riverside Drive Huntington, WV 257059 Phone: (304) 526-5889 FAX: (304) 526-5973 Metallurgical Consultants, Inc. Attn: W. M. Buehler 4820 Caroline PO Box 88046 Houston, TX 77288-0046 Phone: (713) 526-6351 FAX: (713) 526-2964 Naval Surface Warfare Center, Carderock Division Attn: Eric Focht Code 614 9500 Macarthur Blvd West Bethesda, MD 20817-5700 Phone: (301) 227-5032 FAX: (301) 227-5576 Teledyne Allvac Attn: Dr. W. D. Cao 2020 Ashcraft Ave. Monroe, NC 28110 Phone: (704) 289-4511 FAX: (704) 289-4269 Westmoreland Mechanical Testing and Research Inc. Attn: Andrew Wisniewski P.O. Box 388 Youngstown, PA 15696-0388 Mannesmann Rohrenwerke Mannesmann Forschungsinstitut (MFI) Attn: Dr. Weiss Postfach 251160 47251 Duisburg Germany Phone: 011-49-0203-9993194 FAX: 011-49-0203-9994415 ThyssenKrupp VDM USA, Inc. Attn: D. C. Agarwal 11210 Steeplecrest Drive, Suite 120 Houston, TX 77065-4939 Phone: (281) 955-6683 3.11 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited. 3.11.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. 3.12 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. 3.13 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.13.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.13.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted to the NAVSUP WSS Contracting Specialist via eMail. 3.13.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.14 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.15 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results. Certification must include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments must be identified to weld joint and layer. 3.16 Welding Requirements - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval. In addition, the CONSUMED WELD METAL C of C as defined below must be submitted as part of the certification OQE package submitted by the Contractor. Note: These requirements do not apply to tack/spot welds. 3.16.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair). 3.16.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must be submitted at the same time. Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor must state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e. ''WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC'.' WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ'') 3.16.3 The PCO's authorization for the use of weld procedure(s) and qualification data for the specific application as submitted does not mitigate the vendors responsibility to comply with the requirements of S9074-AQ-GIB-010, S9074-AR-GIB-010A/278,248d the contract. 3.16.4 Authority for the repair of Special Repairs in castings, the repair of wrought material, or the repair of forged material must be obtained via request for waiver from the Procurement Contracting Officer. This request must describe the defect; including size, depth, location, and a description of the proposed repair. Repairs deemed minor or nominal in accordance with S9074-AR-GIB-010/278 can be made at contractor discretion in accordance with S9074-AR-GIB-010/278 requirements; however, Weld Procedure Specification (WPS) and Procedure Qualification Record (PQR) submittals are still required. This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application. 3.16.5 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 72 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 72 hour time limit may be modified upon mutual agreement between the vendor and DCMA. 3.16.6 When drawings require hardfacing surface Iron or Nickel content not to exceed 5%, the contractor must verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results must be submitted as part of the qualification data. 3.16.7 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs clearly showing the fusion area) must be submitted for review and show consistent, minimized dilution. All essential elements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution must be in the qualification data and weld procedure, with strict limits placed on each essential element. 3.16.8 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278. 3.16.9 When production or repair welding is required on titanium materials, theapplicable fabrication plan, facilities procedure, training plan, and active welder qualification must also be submitted for review and approval. 3.16.10 If the contractor's fabrication plan, facilities procedure, training plan, or active welder qualification has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the applicable documentation to expedite the approval process. The approval letter must reference the applicable documentation. Prior approval does not guarantee acceptance for this or any future contracts. The contractor's fabrication plan, facilities procedure, training plan, and active welder qualification must be submitted at the same time as the applicable welding procedure(s) and weld procedure qualification data. All documentation must be submitted in a commercially available electronic format, such as Adobe Acrobat PDF. 3.16.11 A Certificate of Compliance is required for all weld filler metals used for production or repair welding, and must include the following: a) Filler Metal LOT number(s) b) Specification and Type c) A positive statement that the vendor has obtained OQE and verified that each LOT of weld filler material conforms to specification requirements. d) A positive statement verifying that the weld filler metals were the correct material type or grade prior to consumption. 3.16.12 When production welds or repair welds are performed by a subcontractor, the requirement for submission of all certification documentation required herein must be passed down to the subcontractor. 3.17 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate. 3.17.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/nonacceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order. 3.17.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor must, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative. 3.17.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award of any contract/purchase order. Suppliers that have a copy of their current quality system procedures on file at the Procuring Activity may request the PCO waive this requirement. 3.17.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately. 3.17.5 Any changes made by the Contractor to a qualified quality system will require re-submittal to the PCO and concurrence by the Government Quality Assurance Representative prior to adoption. 3.18 Contractor Inspection Requirements - The Contractor must maintain adequate records of all inspections and tests. The records must indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected and the nature of corrective action taken as appropriate. Inspection records must be traceable to the material inspected. 3.18.1 The supplier's gages, measuring and test equipment must be made available for use by the Government representative when required to determine conformance with Contract requirements. When conditions warrant, the supplier's personnel must be made available for operations of such devices and for verification of their accuracy and condition. 3.18.2 All documents and reference data applicable to this contract must be available for review by the Government representative. Copies of documents required for Government inspection purposes must be furnished in accordance with the instructions provided by the Government representative. 3.19 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured or performed within the contractor's facility. Such inspection can only be requested by or under authorization of the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies being purchased. When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents must be annotated with the following statement: "A Government inspection is required prior to shipment from your plant. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately." 3.19.1 The prime contractor's program must include procedures to assess the capability of the prospective suppliers to produce the products or supply the services in accordance with the contract, prior to the issuance of any purchase document. 3.19.2 Each sub-tier supplier of material or services for items in Section 3 of this contract must be subjected to a periodic review or audit by the Prime to determine the continued capability of the supplier to control the quality of the products or services specified in the purchase order or contract. 3.19.3 The prime contractor must ensure that the purchased product conformsto specified purchase requirements and this contract. The type and extent of control applied to the supplier and the purchased product must be dependent upon the effect of the purchased pro...

Closes Nov 13, 2026 · 2:00 PM ET
Read more →

CABLE ASSEMBLY

Department of Defense · Navsup Weapon Systems Support MECH  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsSolicitationSmall Business Set Aside - Total

CONTACT INFORMATION|4|N97113A|FBA|771-229-0509|JOSHUA.D.MARTIN76.CIV@US.NAVY.MIL| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|INVOICE AND RECEIVING REPORT (COMBO)|N/A|TBD|N00104|TBD|TBD|SEE SCHEDULE|TBD|N/A|N/A|TBD|N/A|N/A|N/A|N/A|JOSHUA.D.MARTIN76.CIV@US.NAVY.MIL| NOTE FOR CONTRACTOR/ADMINISTRATIVE CONTRACTING OFFICER|3|||| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (OCT 2020)(DEVIATION 2020-O0008)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (OCT 2025)|13|||||||||||||| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2025)(DEVIATION 2025-O0003 AND2025-O0004))|13|335331|800|||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| RFQ closing date has been extended until COB, 10 JUNE 2026. All contractual documents (i.e. contracts, purchase orders, task orders,delivery orders and modifications) related to the instant procurement areconsidered to be ""issued"" by the Government when copies are either depositedin the mail, transmitted by facsimile, or sent by other electrocommercemethods, such as email. The Government's acceptance of the contractor'sproposal constitutes bilateral agreement to ""issue"" contractual documents asdetailed herein. RFQ closing date has been extended until COB, 24 APR 2026. All contractual documents (i.e. contracts, purchase orders, task orders,delivery orders and modifications) related to the instant procurement areconsidered to be ""issued"" by the Government when copies are either depositedin the mail, transmitted by facsimile, or sent by other electrocommercemethods, such as email. The Government's acceptance of the contractor'sproposal constitutes bilateral agreement to ""issue"" contractual documents asdetailed herein. RFQ closing date has been extended until COB, 10 MAR 2026. All contractual documents (i.e. contracts, purchase orders, task orders,delivery orders and modifications) related to the instant procurement areconsidered to be ""issued"" by the Government when copies are either depositedin the mail, transmitted by facsimile, or sent by other electrocommercemethods, such as email. The Government's acceptance of the contractor'sproposal constitutes bilateral agreement to ""issue"" contractual documents asdetailed herein. TO VIEW THE DRAWINGS: Go to www.https://www.sam.gov Click: Contract Opportunities and enter the solicitation number. This gives you access to the Electronic Solicitation. Drawings can be viewed or downloaded. GOVERNMENT SOURCE INSPECTION per FAR 52.246-2 IS REQUIRED. DELIVERY_______________DAYS. All contractual documents (i.e. contracts, purchase orders, task orders,delivery orders and modifications) related to the instant procurement areconsidered to be "issued" by the Government when copies are either deposited in the mail, transmitted by facsimile, or sent by other electronic commercemethods, such as email. The Government's acceptance of the contractor'sproposal constitutes bilateral agreement to "issue" contractual documents asdetailed herein. 1. SCOPE 1.1 This contract/purchase order contains the requirements for manufacture of the CABLE ASSEMBLY . 2. APPLICABLE DOCUMENTS 2.1 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.1.1 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made. 2.1.2 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.1.3 The "Document Changes" section provides supersessions/changes to referenced documents. 2.2 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the drawings shall take precedence. Nothing in this contract/purchase order, however, shall supersede applicable laws and regulations unless a specific exemption has been obtained. DRAWING DATA=2674051 |10001| D| |D| | | | DRAWING DATA=2825437 |10001| C|DW |D| | | | DRAWING DATA=7123520 |53711|AF| |D| | | | DRAWING DATA=7123838 |53711| B| |D| | | | DRAWING DATA=7138634 |53711| A|DW |D| | | | 3. REQUIREMENTS 3.1 Manufacturing and Design - The CABLE ASSEMBLY furnished under this contract/purchase order shall meet the material and physical requirements as specified ;ON DRAWING 7138634-2 (53711) REV A; . 3.2 Marking - Unless marking requirements are specified by a document or drawing cited in this solicitation all items delivered under this contract/purchase order shall be marked and identified in accordance with the applicable Military Standards and Specifications as follows: Mechanical Parts, Assemblies and Equipments - MIL-STD-130 Electrical and Electronic Parts - MIL-STD-1285, Method 1. Electrical and Electronic Parts and Assemblies not covered by MIL-STD-1285-use MIL-STD-130. Electronic Equipment - MIL-STD-454 Requirement Number 67. Electrical Equipment - MIL-P-15024/5 (SHIPS) 3.3 Configuration Control - MIL-STD-973 entitled "Configuration Management", Paragraph 5.4.8, Configuration Control (Short Form Procedure), is hereby incorporated. The Contractor shall submit all Engineering Change Proposals in accordance with MIL-STD-973, Paragraph 5.4.8.2 and Appendix D. Requests for Deviations shall be processed in accordance with MIL-STD-973, Paragraph 5.4.8.3 and Appendix E. Requests for Waivers shall be processed in accordance with MIL-STD-973, Paragraph 5.4.8.4 and Appendix E. (Original and two copies shall be submitted to Contracting Officer, NAVICP-MECH, P. O. Box 2020, Mechanicsburg Pa. 17055-0788.) 4. QUALITY ASSURANCE 4.1 Responsibility for Inspection - Unless otherwise specified in the contract/purchase order, the Contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract/purchase order, the Contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2 Responsibility for Compliance - All items must meet all requirements of this contract/purchase order. The inspection set forth in this specification shall become a part of the Contractor's overall inspection system or quality program. The absence of any inspection requirements shall not relieve the Contractor of the responsibility of assuring that all products or supplies submitted to the Government for acceptance comply with all requirements of the contract/purchase order. Sampling in quality conformance does not authorize submission of known defective material, either indicated or actual, not does it commit the Government to acceptance of defective material. 4.3 Records - Records of all inspection work by the Contractor shall be kept complete and available to the Government during the performance of contract/purchase order and for a period of 365 calendar days after final delivery of supplies. 5. PACKAGING 5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking shall be in accordance with the Contract/Purchase Order Schedule and as specified below. MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE 6. NOTES 6.1 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS) (i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. If you have a problem connecting to the DODSSP Website, please contact either the Subscription Service Desk (215)697-2569, or the Special Assistance Desk (215)697-2667. The DODSSP Customer Service Staff is available every business day between the hours of 7:30 AM and 4:00 PM Eastern Time to answer your questions or assist in solving any problems you might encounter when ordering from the DODSSP collection of Defense specifications and standards, Federal specifications and standards used by DOD, and other DOD standardization documents. Mail requests should be submitted to: Navy Publishing and Printing Service (Subscriptions) Building 4D 700 Robbins Ave. Phildelphia, Pa. 19111 Attn: DODSSP Requests can be transmitted to DODSSP via FAX number (215)697-1462. A. Availability of Cancelled Documents - The DODSSP offers cancelled documents that are required by private industry in fulfillment of contractual obligations in paper format. Documents can be requested by phoning the Subscription Services Desk. B. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. They may be obtained from the publishers of the applicable societies. C. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to: Commander, Indian Head Division, Naval Surface Warfare Center Code 8410P, 101 Strauss Avenue Indian Head, MD 20640-5035 D. Ordnance Documents (OD) - Ordnance Documents may be obtained by submitting a request to: Commanding Officer Naval Surface Warfare Center Port Hueneme Div Code 5A00 Port Hueneme, California 93043 E. On post-award actions, requests for "Official Use Only" and "NOFORN" (Not Releasable To Foreign Nationals) documents must identify the Government Contract Number, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for certification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document. F. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from: Contracting Officer NAVICP-MECH Code 87321 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 G. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered from: Commanding Officer NAVICP-MECH Code 009 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 H. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from: Naval Inventory Control Point Code 1 Support Branch 700 Robbins Avenue Phildelphia, Pa. 19111-5094 I. Interim Changes and Classified Specifications shall be obtained by submitting a request on DD Form 1425 to NAVICP-MECH. 6.2 Ordinance Document (OD) Controlled Items - Award for an item will be made only to the vendor(s) listed on ;OD36190; . A substitute item is not authorized without prior testing and approval. Contractors are cautioned that award of this contract/purchase order will not be delayed solely for the purpose of approving additional sources. Contractors desiring to provide a substitute item are urged to contact the Government PCO to arrange for testing and, if approved, added to the OD as an approved source of supply for subsequent procurements. ON DRAWING 7138634-2 (53711) REV A

Closes Nov 13, 2026 · 4:30 PM ET
Read more →

Reverse Osmosis, Deionization Equipment and PE Water Softene 2026-2027

Dept. of Veterans Affairs · 262-NETWORK Contract Office 22 (36C262)  |  Not listed  |  Posted Nov 6, 2026
Electrical & power systemsSources Sought

This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of the sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses and Veteran Owned Small Businesses interested and capable of providing the services described below. Documentation on technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. The North American Classification System (NAICS) code for this acquisition is NAICS: 221310 Water Supply and Irrigation Systems. PSC: H246 Equipment and Materials Testing Water Purification and Sewage Treatment Equipment. Responses to this notice shall include the following: (a) Company name (b) Address (c) Point of contact (d) Phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned Small Business, Veteran owned small business (i) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. (j) Provide estimated pricing if you were to price today. The Veterans Health Administration (VHA) has a requirement at the Long Beach VA Medical Center, located at 5901 E 7th Street, Long Beach, CA 90822, for Reverse Osmosis, Deionization Equipment and PE Water Softeners Maintenance Service. STATEMENT OF WORK Project Title: Reverse Osmosis, Deionization Equipment and PE Water Softeners Maintenance Service Background: The Long Beach VA Healthcare System (LBVAHCS) requires full-service maintenance to ensure the SPS critical water system meets AAMI ST108 standards. This Reverse Osmosis (RO) water system is used for reprocessing reusable medical equipment (RME). Scope: Contractor shall, without exception, provide all hand tools, diagnostic test equipment, ladders, and anything else necessary to perform the work required to meet the scope. All services shall cover the following Government-owned equipment: 1 SCW Reverse Osmosis, Deionization Upright Skid 8000 gallon per day reverse osmosis 5.5 GPM 5, H5 4X40 thin Film Membranes staged 3-2 housed in Stainless housings 1, Fluid O Tech 4000 series Stainless Steel 10 GPM high pressure pump coupled to a 1.5 HP BALDOR motor 110/220-volt single phase TEFC Pretreatment: Soft Water feed Central Plant Softener supplied by others 1, Automatic Carbon 16X65 4 Cubic Foot 1.5 Clack control Valve 1, Cartridge Pre Filter, Big Grey 1 , 1-5 micron 20 X4.5 Big Grey Distribution Pumps: 2, GOULD s 15SV3FG4C60 5 HP 3Phase 304 SS Vertical pumps 60 GPM @ 70 PSI Storage Tank: 3,500 Gallon conical bottom 52 X81 DEN HARTOG Rotationally molded PE storage tank #CB0500-52, Metal Stand Post Treatment: 4, 1040 1.5 cubic foot Mixed Bed DI Running 2 online and 2 standby running in Series (Not part of sale exchange rental) Flow after RO to Storage Tank 7, 40 5-micron Filters, Housed in 1 SHELCO multi housing 304 Stainless steel 7FOS4 7, 40 Endotoxin Filters, housed in 1 SHELCO multi housing 304 stainless steel 7, FOS4 1, Ultraviolet Sterilizer s Atlantic Model S 5000Crated at 83 GPM running at 60 GPM, 2 NPT Instrumentation/Resistivity/Flow/PLC Mounted in Electrical panel Distribution Pumps : 1, METTLER M800 2 channel Monitor 0-18 MEG/OHM 2, Resistivity Sensor ISM 0-18 Meg 4-20 ma output 1, Horner HE-XW1E6 7 HMI / PLC with 4 AI, 4 Digital inputs and 1, 0-10 PSI 4-20 ma transducer Storage level 1, 0-150 PSI 4-20 ma transducer Loop pressure Inline Analyzers in Metal Cabinet 120/220-volt single Phase: 1, Endotoxin online ENODSAFE NEXGEN MCS and system software 1, TOC online analyzer METTLER 6000i 1, Microbial online analyzer METTLER Bio burden 7000RMS 1, Wall Mount Control Panel HMI/PLC Horner Standards to Adhere to: The Contractor shall adhere to AAMI ST 108 (https://blog.ansi.org/ansi/ansi-aami-st108-2023-water-quality-medical-devices/) Resistivity: 1,000,000 ohms/cm minimum Chlorides: < 10 G/L max Sodium: < 10 G/L max Silica: < 10 G/L max Bacteria: < 10 cfu/ml subset A Endotoxin: < 10 EU/ml Gallons per day: 8000 Distribution Loop Flow: 60 GPM @ 60 PSI Piping Material: SCH 80 PVC Interconnect piping, Stainless loop Ongoing Support Services: Monthly Reverse Osmosis (RO) Service to include: Read Monitor and Log equipment performance Reverse Osmosis and Distribution Replace pre Filter Big Grey 20 5 Micron Check Automatic Carbon Filter pressure and Chlorine removal Check City water TDS and Hardness Change out pre-DI 2-1040 Mixed beds 4- 1040 Mixed Bed DI Monthly Usage 4- 1040 Mixed Bed DI Exchange Log Distribution Pump pressure Log Post Filters Pressure Log Quality, RO/DI 3 Quarterly Sanitization services to include: No Post Filters No UV Lamp 2 Bacteria (Supply and Return) 2 Endotoxin (supply and Return) 2 Semi-Annual Loop Sanitization services to include: 2 Hours MINNCARE or EQUAL Solution Loop Run, 4 Hour total shut down Labs 2 Bacteria (Supply and Return) 2 Endotoxin (Supply and Return) Replace Pre Filters 7, 40 5 Micron Replace Post Filters 7, 40 .04 Endotoxin Replace UV Lamps (annually) Optional Monthly Labs: 2 Bacteria (Supply and Return) 2 Endotoxin (Supply and Return) Labor: The contractor will provide all labor associated with the repair of the equipment covered under the contract agreement. Inadequate or improper repairs performed by the contractor will be correctly repaired at a time convenient to the VA at no additional expense to the VA. There will be no limitation to the number of labor hours provided within the stipulated timeframes of contract coverage. Response Times: Contractor will acknowledge requests by telephone for service within 2 hours. The contractor must always contact the Biomedical Engineering at (tbd) before and after arrival at the site. Reporting Procedures: The Contractor must report to the Biomedical Engineering Department (Building 5, Room 138) to sign the visitor logbook. In addition to signing-in, the Contractor personnel shall wear their VA issued badge and identify him/herself to the Using Service before proceeding to the job site. For services to be performed outside normal working hours, the Contractor must obtain approval from the Biomedical Engineering Point of Contact prior to performing any afterhours work. If the afterhours request is approved, the Contractor must report to the Biomedical Engineering Department (Building 5, Room 138) to sign the visitor logbook and pick up a visitor badge. In addition to signing-in, the Contractor personnel shall identify him/herself to the Using Service before proceeding to the job site. Prior to leaving the facility, the Contractor shall communicate status of equipment to the Using Service and sign out of the logbook in the Biomedical Engineering Department. Note: To ensure proper equipment history documentation, the contractor will forward all preventive maintenance records within 5 working days of completion to Biomedical Engineering. Documentation: For Preventive Maintenance, Contractor will provide a PM checklist to VA Long Beach Biomedical Engineering, listing each action taken to complete the maintenance. Contractor will provide individual results which describe services performed (in sufficient detail to be acceptable to the field inspectors of The Joint Commission). The following information must be provided in each report: Date of service Summary of problem and action taken Parts replaced Labor hours Travel time Equipment serviced (description, Equipment ID #, serial number, etc.) Purchase order number Note: This report must be approved and signed by Biomedical Engineering personnel or their representative. The service report must be provided to Biomedical Engineering within 5 business days of service provided. A copy of each report will be left with Biomedical Engineering. In the event that Biomedical Engineering is not available to receive the service report (outside normal working hours), the service report will be left with the supervising official of the equipment that was serviced; the supervising official will forward the service report to Biomedical Engineering (138M) the next working day. Qualifications: Contractor must be engaged full-time in the service and support of the equipment listed in Section II. Contractor shall have access to complete service manuals Contractor shall have access to software diagnostic keys Contractor Badging: Compliance with Department of Veterans Affairs (VA) Handbook 0735 Homeland Security Presidential Directive 12 (HSPD-12) Program requirements, the Prime Contractor shall coordinate with the Program Office Point of Contact regarding all site visits to the VA Long Beach Healthcare System. Badges are mandatory for all contractors and subcontractors entering the facility. The Prime Contractor is responsible for ensuring that all required information and documentation are submitted to the Program Office Point of Contact with sufficient lead time to allow for proper processing of badge requests. No contractor or subcontractor may begin work onsite without an approved badge, except under emergency conditions as outlined below. Processing Time Badge issuance may take up to 30 calendar days due to required background checks. The Prime Contractor must begin coordination with the Program Office Point of Contact immediately upon contract award to avoid repair, service, or project delays. Onsite Visits for Badging Contractors should anticipate at least two separate onsite visits: One visit for fingerprinting. One visit to pick up the issued badge. Mandatory Training All contractors and subcontractors must complete mandatory training assigned through the VA s electronic Training Management System (TMS) before badges are issued. This training typically requires approximately two (2) hours to complete. Badge issuance and retention are contingent upon successful completion of this training. Emergency Repairs Exception In cases where an emergency repair or service is required and the contractor or subcontractor has not yet been issued a permanent VA badge, a temporary day badge may be issued by VA Police for that emergency only. The Prime Contractor must still ensure that permanent badging is pursued without delay following the emergency event. Period of Agreement: One-year period (12 months). Hours of Coverage: Normal hours of coverage will be Monday through Friday from 5am to 5pm PST. Service and/or repairs must be performed during stipulated hours of coverage unless requested or approved by Biomedical Engineering. Federal Holidays observed by the VA are: Date Holiday Monday, January 01 New Year s Day Monday, January 15 Birthday of Martin Luther King, Jr. Monday, February 19� * Washington s Birthday Monday, May 27 Memorial Day Wednesday, June 19 Juneteenth National Independence Day Thursday, July 04 Independence Day Monday, September 02 Labor Day Monday, October 14 Columbus Day Monday, November 11 Veterans Day Thursday, November 28 Thanksgiving Day Wednesday, December 25 Christmas Day Important information: The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this Sources Sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service-Disabled Veteran Owned Small Business set aside. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov and complete Online Representations and Certifications Application (ORCA). Additionally, all Service- Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be listed as verified on the Veteran Small Business Certification (VetCert) database at https://veterans.certify.sba.gov/. All interested Offerors that can meet the qualifications above should submit information by e-mail to naomi.meza@va.gov. All information submissions shall be received no later than 12:00 PM Mountain Standard Time on Friday, November 13, 2026.

Closes Nov 13, 2026 · 12:00 PM
Read more →
← NewerPage 14 of 33Older →
Scroll to Top